Description
Higher yields / Safe & Reliable / Smart / User-friendly
The single-phase inverter is one of the best options for residential applications due to its smaller size and local LCD display, buttons. With the built-in zero export function (external current transformer is required), it also provides real convenience and comfort for PV system administrators and installers.
Remote shutdown function.
Gallery
Smart monitoring platform
Thanks to the smart monitoring platform, Deye's full-range inverter products support remote shutdown immediately when an accident occurs. Setting parameters and remote FW update, which makes PV plant O&M easier.
- 2 MPP trackers, Max. efficiency up to 97.7%
- Zero Export Application, VSG Application
- String intelligent monitoring (optional)
- Wide output voltage range:
- Anti-PID function (optional)
Technical specifications
Model | SUN-7K-G | SUN-7.5KG | SUN-8K-G | SUN-9K-G | SUN-10K-G | SUN-10.5KG |
---|---|---|---|---|---|---|
Input side | - | - | - | - | - | - |
Maximum DC Input Power (kW) | 9.1 | 9.8 | 10.4 | 11.7 | 13 | 13.7 |
Maximum DC input voltage (V) | 550 | 550 | 550 | 550 | 550 | 550 |
Start-up DC input voltage (V) | 80 | 80 | 80 | 80 | 80 | 80 |
MPPT working range (V) | 70~500 | 70~500 | 70~500 | 70~500 | 70~500 | 70~500 |
Maximum DC Input Current (A) | 13+26 | 13+26 | 13+26 | 26+26 | 26+26 | 26+26 |
Maximum Short Circuit Current (A) | 19.5+39 | 19.5+39 | 19.5+39 | 39+39 | 39+39 | 39+39 |
Number of MPPT/strings per MPPT | 2/1+2 | 2/1+2 | 2/1+2 | 2 / 2+2 | 2 / 2+2 | 2 / 2+2 |
Model | SUN-7K-G | SUN-7.5KG | SUN-8K-G | SUN-9K-G | SUN-10K-G | SUN-10.5KG |
---|---|---|---|---|---|---|
exit side | - | - | - | - | - | - |
Rated output power (kW) | 7 | 7.5 | 8 | 9 | 10 | 10.5 |
Maximum Active Power (kW) | 7.7 | 8.25 | 8.8 | 9.9 | 11 | 11.55 |
Nominal AC mains voltage (V) | 220/ 230(Optional) | 220/ 230(Optional) | 220/ 230(Optional) | 220/ 230(Optional) | 220/ 230(Optional) | 220/ 230(Optional) |
AC Mains Voltage Range (V) | 160Vac~300Vac(this may vary with grid standards) | 160Vac~300Vac(this may vary with grid standards) | 160Vac~300Vac(this may vary with grid standards) | 160Vac~300Vac(this may vary with grid standards) | 160Vac~300Vac(this may vary with grid standards) | 160Vac~300Vac(this may vary with grid standards) |
Estimated Grid Frequency (Hz) | 50 / 60 (Optional) | 50 / 60 (Optional) | 50 / 60 (Optional) | 50 / 60 (Optional) | 50 / 60 (Optional) | 50 / 60 (Optional) |
Operating phase | single phase | single phase | single phase | single phase | single phase | single phase |
Rated AC Mains Output Current (A) | 30.4 | 32.6 | 34.8 | 39.1 | 43.5 | 45.7 |
Maximum AC output current (A) | 33.5 | 35.9 | 38.3 | 43 | 47.8 | 50.2 |
Output Power Factor | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging |
Mains power THD | ||||||
DC Injection Current (mA) | ||||||
Power frequency range | 47~52 or 57~62 (Optional) | 47~52 or 57~62 (Optional) | 47~52 or 57~62 (Optional) | 47~52 or 57~62 (Optional) | 47~52 or 57~62 (Optional) | 47~52 or 57~62 (Optional) |
Efficiency | - |
---|---|
Max.Efficiency | 97.70% |
Euro efficiency | 97.50% |
MPPT efficiency | >99% |
Protection | - |
---|---|
DC reverse polarity protection | Yes |
AC Short Circuit Protection | Yes |
AC output overcurrent protection | Yes |
Output Overvoltage Protection | Yes |
Insulation Resistance Protection | Yes |
Earth fault monitoring | Yes |
Island protection | Yes |
Temperature protection | Yes |
Integrated DC Switch | Yes |
Remote software upload | Yes |
Remote operating parameters change | Yes |
Overvoltage protection | DC Type II / AC Type II |
General data | - |
---|---|
Size (mm) | 330W×410H×198.5D |
Weight (kg) | 15.7 |
Topology | Transformerless |
Internal consumption | |
Running temperature | -25~65℃, >45℃ derating |
Degree of protection | IP65 |
Noise emission (typical) | ≤25dB |
Cooling concept | Natural cooling |
Maximum Operating height without reduction | 2000m |
Designed Lifetime | >20years |
Mains connection Standard | IEC 0-21, VDE-AR-N 4105, NRS 097, IEC 62116, IEC 61727, G99, G98, VDE 0126-1-1, RD 1699, C10-11 |
Operating environment Humidity | 0-100% |
Safety EMC/Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
features | - |
---|---|
DC connection | MC-4 mateable |
AC connection | IP65 rated plug |
reproduction | LCD 1602 |
Couple | RS485/RS232/Wi-Fi/LAN |